Sysmex uf1000i user manual

Using fluorescence flow cytometry, the uf i offers two separate channels. In conclusion, the sysmex xs i demonstrated good analytical performance, is able to generate a complete blood count with fivepart differential on low. Fully automated, rapid sample processing enhances laboratory workflow, improves turnaround times and frees skilled technologists to devote their time to other laboratory priorities. Analysing differentials consists of a cytochemical reaction of the cells with a reagent, followed by a fluorescence flow cytometric analysis. Sysmex corporations corporate philosophy defines its mission as shaping the advancement of healthcare. The sysmex ufi is a urine flow cytometer that uses two separate channels for counting blood cells and bacteria. Sysmex ufi analyzer standardizes and provides fully quantitative urine sediment results using highsensitivity fluorescent flow cytometry. In this study, 358 urine samples were analyzed with the sysmex uf i in parallel with manual microscopy, gram stain and bacterial culture, the latter considered the gold standard. Urine culture is the gold standard for diagnosis, but new techniques, such as flow cytometry analysis fca, have been introduced. Carefully read the operators manual for correct use of the unit. Sysmex america is lighting the way to better health with diagnostic solutions that transform the future of healthcare and contribute to healthier lives. Evaluation of the sysmex ufi urine flow cytometer in. Using a unique and advanced diode laser bench, sysmex fluorescent flow cytometry provides the sensitivity needed for measuring and differentiating cell types in whole blood and body fluid.

Pdf evaluation of a new automated cell analyzer sysmex. Sysmex ufi urine cell analyzer system overview online. Xp300 quick guidedocument number 1051cfl, revision 2 june2014 page 3 quality control analysis running qc 1. The aim of the present study was to evaluate fca characteristics regarding bacteriuria, leukocyturia, and erythrocyturia in relation to cultured uropathogens in specimens from patients. Manufacturer specifications uf i, sysmex please note. Service manual sysmex xn service technicians forum. They reflect our drive for excellence and our profound love of knowledge. It will continue to be of your service in finding specific information about this instrument. Xp300 quick guidedocument number 1051cfl, revision 2 june2014 page 2 daily operating procedures preoperation checks verify the following before powering on the xp300. Theres a novel sample explorer to simplify sample management, and you can connect to sncs, the sysmex network communication system, with iqas online sysmex s online quality control. The sysmex xsi showed good correlation with xe2100, cd4000 and the manual reference leucocyte differential.

A surfactant in the reagent induces the lysis of red blood cells. Log in please enter your email address and password. The poch100 i hematology analyzer, designed for laboratories testing up to 25 samples per day, has the smallest footprint of any hematology analyzer on the market. Overall flagging sensitivity and specificity were 91% and 48%, respectively. News sysmex korea, hbsag, hiv test reagent received mfdss approval of ivd class 4 read more. Evaluation of the sysmex ufi flow cytometer for ruling out bacterial urinary tract infection. Pdf evaluation of a new automated cell analyzer sysmex uf. By automatically reanalysing samples for which results are considered unreliable, it significantly reduces manual interventions and frees up time and resources. It can be used as a standalone analyser, or as part of the modular unseries for a truly walkaway, seamless urinalysis workplace solution from sample loading to the final digital image. Thank you for your interest in our instructions for use ifu, certificates, package inserts or standard operating procedures.

The sysmex xs i showed good correlation with xe2100, cd4000 and the manual reference leucocyte differential. Sysmex uf i medical laboratory equipment sysmedlabs. The clinitek auwi pro automated urinalysis system combines two trusted technologies on a single platform to provide true walkaway drypad urine chemistry testing and sediment analysis. General services administration federal supply service. Warranty roche diagnostics makes no warranties for the sysmex xe2100 system host interface manual beyond those set forth in the operators manuals for the sysmex xe2100 analyzer. The results of the first analysis are displayed in the x1 column when completed as shown in figure 24. The sysmex ufi using a dedicated bacterial channel and additional sidescatter information aids to revise a new exploration of urinalysis flow cytometry. Sysmex uf ia new generation automated urine particle analyzer, a fully automated urine particle analyzer for the clinical lab. Sysmex uf is a new flow cytometry for the analysis of urine based on a laser diode technology using specific compounds for the staining nucleic acids, characterized by a. Sysmex ufi urine analyzer manufacturer specifications. In conclusion, the sysmex xsi demonstrated good analytical performance, is able to generate a complete blood count with fivepart differential on low. Email address remember password dont have an account. The xsi is also a great backup or nightshift solution. This clinical laboratory training qualifies for continuing education units ceu.

Sysmexs proven ufi technology offers laboratories a breakthrough in automation, standardization and efficiency. In fact, we proved the performance of the sysmex ufi bacteria count in reducing urine cultures for uti is superior to uf100s. The new uc3500 is a fully automated urine chemistry analyser that offers particularly high clinical value. Userdefinable flaggingof all the parameters for rapid result. For blood cell counts we use fluorescence flow cytometry, e. Using a total of 700 patient samples, results from the sysmex xs i were compared with those from a sysmex xe2100, an abbott cell dyn 4000 and the manual reference leucocyte differential. Mix the control blood according to the package insert. Sysmexs proven technology offers laboratories a break. Sysmex sustainability data book sustainability sysmex. Fast screening methods that can reduce the necessity for urine cultures will have a large impact on overall turnaround time and laboratory economics.

Uf ii control leveyjennings and xbar quality control programs accessories graphic printer dimensions weight main unit. Uf i highquality urinalysis at the touch of a button our new ufseries of urinalysis devices is unique. Service manual sysmex k, user manual coulter maxm july 02, 2014 10. Sysmex ufi is a new generation automated urine particle analyzer that offers laboratories a breakthrough in automation, standardization and efficiency. The uf5000, based on sysmexs globally renowned fluorescence flow cytometry ffc, represents the latest in urinalysis technology. Remove the cap and set control blood container to the sample probe.

Sysmex ufi urine cell analyzer system overview online training identify the main system components and describe their function. Technology urine flow cytometry two stains with fluorescent dye. The sysmex logo, uf ii sheath, uf ii packsed, uf ii packbac, uf ii searchsed, uf ii searchbac, uf ii control are used, pending andor registered trademarks belonging to sysmex corporation biomerieux sa rcs lyon 673 620 399. Urinary tract infections utis are the second most common bacterial infection. Screening for urinary tract infection with the sysmex uf. Sysmex uf is a new flow cytometry for the analysis of urine based on a laser diode technology using specific compounds for the staining nucleic acids, characterized by a threshold of. Manual mode sysmex sf3000 operators manual revised december 1995 29 when x control program is used. Urine sample material is dropped onto each pad of a dedicated test strip within the analyser. User maintenance has been reduced further with minimal automatic shutdown time. Its innovative hematology, urinalysis and flow cytometry testing technology is reshaping the world of diagnostics across the u. We are very aware of the fact that we can and do make a genuine positive contribution to our domains in the healthcare industry, and therefore to the health of individuals. Sysmex sustainability data book in fiscal 2019, we changed the name of the sysmex sustainability report to the sysmex sustainability data book. Sysmex kx21 operators manual revised october 1998 vii introduction thank you for purchasing the sysmex automated hematology analyzer kx21. Uf i is a fully automated, urinary screening system which bases its objective.

A new generation automated urine particle analyzer sysmex. The sysmex uf i automated urine particle analyzer with the siemens clinitek atlas automated urine chemistry analyzer. On that basis, we provide diagnostic instruments, reagents and software throughout the world. Seamless integration of the clinitek novus automated urine chemistry analyzer and the sysmex ufi urine particle analyzer delivers loadandgo.

The aim of the present study was to evaluate fca characteristics regarding bacteriuria, leukocyturia, and erythrocyturia in relation to cultured. Performance evaluation of the sysmex xsi automated. The uf i enhances work flow efficiency in the clinicl laboratory by offering true walkaway capability, freeing the technologist from many of the laborintensive steps of manual urine microscopy. The uf i offers accurate and precise particle counts on uncentrifuged urine samples. To enhance security, these are located on a separate server and therefore on a separate website.

We assume your consent, as you are making use of this website. Identify the methodology used to analyze the formed elements. The challenge is real, especially when you are buying a new analyzer, implementing sysmex wam middleware, or have newly hired technologists. In fact, we proved the performance of the sysmex uf i bacteria count in reducing urine cultures for uti is superior to uf 100s. Sysmex europe gmbh, bornbarch 1, 22848 norderstedt, germany, phone. Flow cytometry analysis using sysmex ufi classifies. The principle of fluorescence flow cytometry is used in different analysers for haematology and urinalysis. If the instrument is used continuously in that state, there is a hazard that fire, electrical shock, or. Requiring only 15 l of edta whole blood for reporting 17 clinical. Clinical haematology is an intensive, exciting, rewarding and demanding specialty. A cookie is a simple small file sent with the pages of this website and stored by your browser on the hard disk of your computer. At sysmex, we believe education and training is a journey and we are beside you every step of the way. None of the equipment posted for sale on is owned by medwow, should you have any questions regarding a specific item, please direct them to the appropriate seller by making use of the available communication channels on the items page.

Sysmex kx21 operators manual revised october 1998 iii warning in the event the instrument emits abnormal odor or any smoke, turn off the power immediately and disconnect the power plug from the wall socket. Sysmex ufi flow cytometer capability to discriminate. Sysmex ufi analyzer urinalysis automation laboratory stack. Sysmex latin america and the caribbean rua joaquim nabuco 615 bairro cidade jardim sao jose dos pinhais parana brasil cep 83040210 tel. Pdf performance evaluation of the sysmex xsi automated. Sysmex uf i analyzer standardizes and provides fully quantitative urine sediment results using highsensitivity fluorescent flow cytometry workstations are linked by a common sample track and integrated with powerful workflow management software for unattended operation with complete confidence. The sysmex uf i is a urine flow cytometer that uses two separate channels for counting blood cells and bacteria.

The diagnosis of urinary tract infection uti by urine culture is timeconsuming and can produce up to 60 to 80% negative results. The sysmex uf i using a dedicated bacterial channel and additional sidescatter information aids to revise a new exploration of urinalysis flow cytometry. The entire sequence, starting from sample aspiration, to colour comparison and final output of the results is fully automatic. We have evaluated the detection of bacteria and leukocytes by a new urine. Sep 24, 2018 community forums for sysmex uf i relating to user manual in english on medwrench. This publication is intended to complement integrated reporting content, and contains detailed information related to sysmexs environmental, social and governance esg efforts. Using a total of 700 patient samples, results from the sysmex xsi were compared with those from a sysmex xe2100, an abbott cell dyn 4000.

1405 1193 705 825 722 917 614 1274 700 801 102 707 955 1279 556 488 118 1176 381 1003 1374 459 305 264 759 1534 512 687 820 528 1127 490 651 726 152 600